Counterweighted
Baffle
The
counterweighted baffle system allows the 12" baffle to
become automatic without the use of a static pressure control.
This system is ideal for use in areas like preheated hallways,
etc. Specifications: 3,000 CFM R.O. 46-1/2" Width X 13-1/2"
Height.

Butterfly
Style Baffle
The
butterfly style allows for air to be directed in both directions
and dropped straight down on the livestock as needed.

C2000 Ceiling Air Inlet This ceiling inlet made of ABS plastic
can be used year round. AS a result of the inlet being four
sided, room temperature is more consistent and air distribution
is improved. The C2000 is insulated, therefore reducing condensation.
Operating automatically off of the negative pressure supplied
by the exhaust fans eliminates the need for manual controls,
cables or pulleys. Pressure washing is simple with the all
plastic construction.
|
 |

Adjust-a-Baffle
From
the originators of the plastic adjustable air baffle comes
the finest most versatile baffle type air delivery system
available. One-inch thick polystyrene with a rugged fiberglass
coating fastened to UV stabilized PVC channels make any size
a possibility. A flexible PVC hinge and sealing strip slide
into the PVC channel making installation a snap. Adjust-a-Baffle
is available in 8", 10", 12", 16", 18",
20" and 24" sizes.

BIL3000/4000
Air Inlets
The
BIL 3000 and 4000 inlets are second stage shutter type air
inlets to be used in hallway to room application. As second
stage inlets, they do not open until the first stage ceiling
inlets are at optimal operation. When these inlets are opened,
air is directed upward then gradually moves horizontally.
Automatic
Wall Inlets
These
1250 cfm inlets are molded of tough plastic for long life,
operate automatically by negative pressure and require little
attention from the operator. The system consists of two parts;
the outside hood (shown right) and the inside balanced door.
When the system fans are operating, the inside unit opens
automatically to provide required circulation. A second door
is provided for latching closed during winter. Both inside
and outside parts are designed to secure directly to the building
walls.
|
Ceiling Inlet Chart
|
|
CAI-3.0
r.o. 17" x 17"
cfm @ .10" STATIC PRESSURE 991
cfm @ .125 static pressure 1195
|
CAI-3.0
r.o. 17" x 17"
cfm @ .10" STATIC PRESSURE 991
cfm @ .125 static pressure 1195 |
|