AP
Climate Controllers
Environmental
controls are the core of any ventilation system. Having the proper
controls for heating, cooling, air inlets, etc. and making them
user-friendly is not always easy. Durability in the harsh environment
of a livestock facility is also high on the priority list. AP's
line of TC4 and TC5 controls has addressed all of these issues and
more...
|
|
|
 |

Remote Access
By
adding the optional PC3-INT interface to any group of the TC4 and
TC5 controls, operation can be monitored and fully programmed from
a PC either on site or via modem anywhere there is a phone line.
This is extremely advantageous with remote and multiple sites. This
interface can also be added at a later date.
See
the controls table below for brief description of available panels.
For an in-depth description, contact your AP representative.
|
|
All these
features at your fingertips:
Microprocessor based
Temperature ramping
CSA approved
Water resistant enclosure
115V/230V - 50/60Hz
Fused outputs
Surge protected
Optional multiple sensors
PC compatible with interface
Sensors can be extended to 500'
Temperature range 35-99 degrees F
High/Low registration
|
|

Relay
Panels
AP relay panels are available in metal boxes and nema 4 plastic enclosures.
Heavy contactors transfer loads so the controls don't carry heavy
electrical current. Panels come with manual override for emergency
operation of fans, heater, curtains, etc. Back-up thermostats help
protect your investment in the event of a control failure. Easy to
read laminated wiring diagrams (cataloged by our technicians) make
service an easy task. |
 |
|
MPV |
10
amp variable speed booster control (for controls with 1 var. speed) |
| |
 |
MPVV |
20
amp variable speed booster control (for controls with 2 var. stages) |
| |
|
PC2-COM |
Communications
circuit board for TC4 controls when interfacing w/ PC3-INT |
| |
|
PC3-INT |
Computer
interface control with software alarm, and display |
| |
|
PF6 |
Potentiometer
feedback control with display (must be used with a TC4 or TC5 series
control) |
| |
|
TC1-1SD |
Single
stage on-off control with display |
| |
|
TC1-C |
Variable
speed control without display |
| |
|
TC1-CD |
Variable
speed control with display |
| |
|
TC1-MFS |
Manual
variable speed control |
| |
|
TC1-NV |
Natural
ventilation control without display |
| |
|
TC4-1CH |
Chimney
actuator control |
| |
|
TC4-1V2S |
1
variable, 2 on-off stages with display |
| |
|
TC4-1V3S |
1
variable, 3 on-off stages with display |
| |
|
TC4-1VHB |
10
amp variable control for heat mats or lamps with display |
| |
|
TC4-4SD |
4
stage on-off control with display |
| |
|
TC4-NV2S |
Natural
ventilation control, with display and 2 on-off stages |
| |
|
TC4-NVS |
Natural
ventilation control, with display and 1 on-off stage |
| |
|
TC4-T10 |
1
channel 24 hour timer with display |
| |
|
TC4-T30 |
3
channel 24 hour timer with display |
| |
|
TC5-2V2SA |
2
var., 2 on-off stages, alarm stage, display, humidity probe optional |
| |
|
TC5-2V4SA |
2
var., 4 on-off stages, alarm stage, display, humidity probe optional |
| |
|
TC5-1V6SA |
1
var., 6 on-off stages, alarm stage, display, humidity probe optional |
| |
|
TC5-8SDA |
8
stage on-off, alarm stage, display, humidity probe optional |
| |
|
TC5-2V8SA |
2
var., 8 on-off stages, alarm stage, display, humidity probe optional |
| |
|
TC5-1V10SA |
1
var., 10 on-off stages, alarm stage, display, humidity probe optional |
| |
|
TC5-12SDA |
12
on-off stages, alarm stage, display, humidity probe optional |
| |
|
TC5-1N4FIA |
Power
natural ventilation control, 1 var., 1 on-off, 1 curtain, 1 mist,
1 heat, alarm stage, display, humidity probe optional |
| |
|
TC5-1N5FIA |
Power
natural ventilation control, 1 var., 1 or 2 on/off stages, 1 curtain,
1 timed mist, 2 heat-zone or cascade, alarm, display, humidity probe
optional |
| |
|
TC5-1N8FA |
Power
nat. vent. control, 2-var., 1 on-off, 1 curtain, 1 on-off, 1 timed
mist, 3 heat zone or cascade, alarm, display, humidity probe optional |
| |
|
TC5-T1A |
11
stage power/natural/tunnel control, 1 var., alarm stage, display,
humidity probe optional |
| |
|
TC5-T6A |
11
stage power/natural/tunnel control, alarm stage, display, humidity
probe optional |
| |
|
TC5-3N3S |
Two
zone natural ventilation control w/optional chimney control, zoned
heat, circulation fans, alarm stage, display |
|