AIRFLOW DISTRIBUTION
Inlets
AIRFLOW DISTRIBUTION
Highlights
- Air inlets and tunnel doors provide precise control and distribution of airflow into or out of any type of ventilation system.
- Energy savings and low maintenance.
- Power washer friendly.
- Corrosion resistant construction.
Built to Perform
Cut to length on site for a customized-fit
Actuated PVC Wall Inlets
Opens automatically based off negative static pressure supplied by the exhaust fans. Available in bi-fold or four-sided models for ceiling inlets, and in top-hinged counter-balanced model for wall inlets. Corrosion-resistant plastic and aluminum housing and doors. Hardware package and insulation stop with every inlet. Panel dimensions are 1.5″ thick x 30″ tall x 24’ long.
Adjust-A-Baffle™ Systems
Constructed of one-inch thick polystyrene with a rugged plastic coating fastened to UV-stabilized PVC channels. Any length possible in 8″, 12″, 16″, 18″, and 24″ sizes. Flexible PVC hinge and sealing strip slide into the PVC channels. Stainless steel cable or rod hardware packages available.
Bi-flow ceiling inlet sizes: 1000 & 2700 CFM
Non-Actuated Ceiling and Wall Inlets
Non-actuated ceiling and wall inlets models are available with plastic or aluminum housing. The counter-weighted baffle system allows the 12″ baffle to become automatic without the use of mechanical static pressure control.
Specifications
Maximum Inlets Per Actuator & Maximum Run Length
| Actuator Type | Max. Number of Inlets Per Controller (1:1 Pulley Ratio) | Max. Number of Inlets Per Controller (2:1 Pulley Ratio) | Max. Run Length (ft.) |
|---|---|---|---|
| Auto-Air Controller | 16 | 24 | 150 |
| Curtain Controller | 48 | 72 | 150 |
* for maximum accuracy, limit run length to 150 feet.
Rated Airflow Inlet Opening Actuator Travel
| Inlet Positioning at Full CFM Rating | Inlet Positioning Restricted to Horizontal | |||
|---|---|---|---|---|
| Inlet Model | Rated CFM @0.10 Static Pressure | Maximum Opening (in.) | Rated CFM @0.10 Static Pressure | Opening at horiz. (in.) |
| ACI-2-4000 | 4000 | 8.0 | 2400 | 4.5 |
| ACI-2-1500 | 2000 | 8.0 | 1400 | 4.5 |
| ACI-4000P2 | 4100 | 8.0 | 2500 | 4.5 |
| ACI-2500P2 | 2200 | 8.0 | 1500 | 4.5 |
| ACI-2-3000 | 3100 | 12.0 | 2100 | 5.0 |
| ACI-1-2500 | 2500 | 12.0 | 1150 | 5.0 |
| ACI-2700P | 2400 | 9.0 | N.A. | N.A. |
Refer to the actuator manual to set limit switches in the actuator for the proper amount of travel needed.
If the pulley ratio is 1:1 the travel needed in the actuator is the same as the maximum opening listed above.
If the pulley ratio is 2:1 the travel needed in the actuator is twice the maximum opening listed above.